1. Outstanding features
Excellent results stability: high accuracy and error <1%
The system accurately scans the area and ability to recombine with the marked cross-laser pointer, resulting in accurate and repeatable measurement data.
Quick scan time
- Bone spine: 85 seconds.
- Thighs: 65 seconds
Slow scan time
- Bone spine: 187 seconds.
- Thighs: 120 seconds
Forearm: 5 minutes 53 seconds
- Comprehensive report: DEXXUM T provides detailed inspection information. Patients' outcomes were compared to those of the common (T-score) and the corresponding age (Z-score)
- Real-time scan: Up to 3 areas for single scan (Spine and femur double)
- Region of Interest: Regionalization of interest automatically after each measurement.
- Set up automatic optimization with patient size (Calculated from the patient's height and weight).
- Correction: Delete or add functionality to separate the bone and tissue to reduce errors in BMD calculations (as a result of fracture, or surgical implants).
- Automatically back up data by week. The software can be adjusted to control the actual measurement.
Multi-Report function allows you to print measurement results of many parts: neck, thigh bone, spine bone on the same page.
- Check daily to ensure stability of equipment for regular operation.
- Easily enter data and manage to register and edit patient details and BMD measurements.
- Absolutely safe, no need for doctor's lead coat: radiation level <0.1S and 1m distance from X-ray source is negligible.
- Support for color photos
- Indicate the area of interest for the representative.
- Minimize position errors by using a cross-hair laser pointer for the measurement and identification locations.
- Multilingual support: English, German, Spanish, Russian, Chinese, Korean.
- Automatic soft tissue division
- Comparison of data systems
- Supports DECOM system (image transmission)
- Report can be adjusted to integrate to integrate with hospital name / logo
II. Specifications:
X-ray system: DEXA (dual energy X-ray absorption)
- Scanning method: narrow beam
- Scan position: Spine AP, Thigh (Double Thigh), Forearm
- Type of scan: Continuous scan (AP spine, double thigh)
Quick scan time
- Bone spine: 85 seconds.
- Thighs: 65 seconds
Slow scan time
- Bone spine: 187 seconds.
- Thighs: 120 seconds
- Forearm: 5 minutes 53 seconds
- With the bone-to-bone ratio algorithm, the measurement error is reduced.
The error rate is 1%.
Environmental requirements (self-protection for source temperature)
+ Ambient temperature: 17-30oC
+ Humidity: 20-80% (non-condensing)
- Measurements: BMD, BMC, area, tissue thickness, body fat
- Calibration system: automatic calibration, daily QC illusion
- Patient positioning: laser positioning (positive type)
- Image transmission: DICOM system
- Source: 100-120VAC, 50Hz, 60Hz / 220VAC.50Hz, 60Hz
- Operating System: Windows XP, Windows Vista
- Display: LCD (1280 x 1024 pixels)
- Printer: Color ink with 300 x 300 dpi resolution
- Size: + Standard: 2000 x 800 x 1221mm
+ Normal: 1900 x 800 x 1221mm
+ Block: 1850 x 800 x 1221mm
- Weight: 130.5 kg